Bycotest C5 cleaner Red and white method.
Crack detector product C5
CLEANER BYCOTEST C5 AEROSOL 400ML
Art.-no.
0890201090
EAN 4053479959566
-
Show availability at another Würth Center
In order to check the stock in a Würth Oy branch, please log in.
If you have any questions, please call our service hotline at 010 308 6700.
Do you want to register as an Online Shop user?
Please go to the eShop registration page.
Exclusively for trade customers
Register and access more than 75 000 products
Carefully clean the testing surface with Bycotest C5.
Spray Bycotest RP20 penetrant solution onto the testing surface and allow it to set for 10–20 minutes.
Remove any excess penetrant solution with water or C5. Do not spray the cleaner directly onto the surface to be inspected. The surface must be dry before you spread the developing agent.
Shake the D30 developing agent can and spray a layer of the developing agent onto the surface to be inspected. The suitable spraying distance is around 20 cm.
Any defects will appear a moment later as red lines or dots.
The developing agent will usually take around 15 minutes to work. Remove the developing agent by brushing the surface with water.
Spray Bycotest RP20 penetrant solution onto the testing surface and allow it to set for 10–20 minutes.
Remove any excess penetrant solution with water or C5. Do not spray the cleaner directly onto the surface to be inspected. The surface must be dry before you spread the developing agent.
Shake the D30 developing agent can and spray a layer of the developing agent onto the surface to be inspected. The suitable spraying distance is around 20 cm.
Any defects will appear a moment later as red lines or dots.
The developing agent will usually take around 15 minutes to work. Remove the developing agent by brushing the surface with water.
Product information
Datasheets(X)
null | null |